Circuit plan smart lock 3
Installation instructions
...
2. Fix the retaining nut with 2Nm.
Establish power supply:
Pin 1 cable colour PINK: 12 – 48 24 Volt DC
Pin 2 cable colour BROWN: GND, Minus, 0 Volt
Pin 3 cable colour YELLOW: Optional external
presence detection, set polarity in the software
Pin 4 cable colour GREY: Relay closed contact
port 1, potential separated
...
Dimensions without connection cable | Diameter x Length:: Ø 38 x 58 mm Drilling diameter: Ø 30 mm Thread: Ø 30 x 1 mm, 14 mm long |
Weight without connection cable | 40 g |
Casing | transparent, protection IP 54, accord. To DIN EN 60529 |
Attachment | Screw connection with nut Ø 30 x 1 mm |
Temperature range | –10 to +65 °C |
Working relay | Signal „Driver logged in“ Potential free close-contact of MEK, Max. Load of the contacts in MEK 12 V: 2 A / 24 W | 24 V: 2 A / 48 W | 48 V: 1,25 A / 60 W • Open: Forklift out of service, NOT permitted to drive or lift • Closed: Forklift in use, permitted to drive or lift |
Entry presence detection | Plus 5 up to 120 V DC GND 0 up to > 1 V DC |
Lenght of connection cable | 2 meters |
On – and Off switch | Via user transponder, display with LEDs |
Power supply | Nominal battery voltage: 12 – 48 24 V DC |
Power consumption / performance | < 150 mA < 3 W |
Programming of user data | Bluetooth |
Transponder | 125 kHz
|
Response range of the transponder | Up to approx. 20 mm |
Data receipt | Battery-backed (5 years battery life) |
Certificate | CE EMV DIN EN 12895 |
...