Important:
If the presence detection is used together with radio data transmission, there must be a distance of at least 70 cm between the radio module and the presence detection in order to rule out interference
New version since 2014
Since April 2014 the Presence Recognition comes with a plug.
The plug is connected to the RAD slot of motherboard version basic VI.
Old version
With older motherboards the plug has to be cut off.
The three wires (white, brown, green) are connected according to the illustration below:
white = positive (Potential 12 – 24 V)
brown = negative (Potential 0 V / GND)
green = Signal „Driver seats“